Expert Summary Reports – comments from The Chemours Company FC,
LLC - Thermal and Specialized Solutions segment.
Thank you for providing summary reports for each sector of the corresponding Call for Evidence
questionnaire. It was useful to have a clear understanding of the methodology and definitions used in
the authorities’ analyses. After carefully reviewing these reports with our internal experts, we would like
to share some of our observations for your consideration.
Below, you will see a set of comments in which we highlight parts of the summary reports where
our data on the F-gas market differs from the relevant report drafted by REACH-competent authorities
and their consultants. We hope for the opportunity to clarify these comments should it be helpful, to
ensure a shared complete and accurate understanding of the F-gas market in Europe.
Contents
PFAS Production (Manufacturing) – Comments on Consultation Report Summary .................................... 2
Application of Fluorinated Gases (F-Gases) in the European Economic Area – Comments on Consultation
Report Summary ........................................................................................................................................... 5
Report summary F-gas uses – Comments on Consultation Report Summary ............................................. 8
Electronics & energy – Comments on Consultation Report Summary ....................................................... 17
Transportation – Comments on Consultation Report Summary ................................................................ 19
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0002.png
PFAS Production (Manufacturing) – Comments on Consultation Report
Summary
Link to report summary:
https://bit.ly/3mTQw9Y
[Page 3, 1.1 Objectives of the study]
Page 3, Section 1.1 details the study’s methodology, including the 152 stakeholders invited by
email to participate in the project. When describing unsuccessful efforts to identify and contact
Asian PFAS stakeholders, however, no quantifiable specifics are provided. It would be helpful to
know the total number of Asian PFAS stakeholders that were contacted to participate and the
actual number that did participate. If the total number of Asian PFAS stakeholders invited to
participate cannot or will not be disclosed, then please provide the percentage of the total
stakeholders (152) that were Asian.
Page 3, Section 1.1 also notes the study team asked survey respondents to classify their reported
substances into one (or more) of 23 groups, as described in work carried out by the OECD. We
recommend including a link to the referenced report to provide context and clarify which 23 groups
the OECD identified.
[Page 6, 2.1 Annual EEA (EU27+NO/IS/LI/UK) production/processing tonnage volumes (last 15-20 years)]
Page 6, Section 2.1,
Table 1: PFAS manufactured/processed in the EEA (in tonnes)
lists PFAS
manufactured or processed in the EEA, but neither the table nor the referenced literature include a
time-period to contextualize how current the production figures are. This context is necessary and
highly relevant to appreciating the data because there was an aggressive phasedown in the EU
due to the F-gas Regulation, effective 1 January 2015. Hence, production figures for F-gases are
vastly different in 2015, 2020 and so on. Without this context, we are concerned that the provided
production figures may not be correctly reflected in this Table.
Page 6, Section 2.1,
Table 1: PFAS manufactured/processed in the EEA (in tonnes),
it would also
be helpful to understand how F-gas is being defined in this context.
[Page 7, 2.1.1 Literature Review]
Page 7, Section 2.1.1,
F-gases,
claims that HFCs, in particular HFC-134a, is produced in
“negligible quantities” in EEA and are therefore not reported. Based on our understanding of the
market data, we agree that the ECHA registration likely exceeds 10KT. Further, it is known that
there is production/capacity of HFC-134a in Germany on an industrial scale. Given these figures, it
would be helpful to understand what constitutes “negligible” in this context, and what threshold is
being used to determine it.
Page 7, Section 2.1.1,
F-gases,
also notes that the EU’s capacity for production of HFC-152a is
around 5,000 tonnes and overall, in 2012, the EU consumption was less than 10,000 tonnes.
However, based on available market data, this figure may be overstated. There is no known
production of HFC-152a in the EU and according to the EEA Report No. 15/2020, the total supply
to the EU was 3100MT in 2019.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
Page 7, Section 2.1.1,
F-gases,
also claims that the EU is the only region that produces HFC-
365mfc, with 15,000 tonnes produced per year. However, this figure is likely overstated given the
available market data for this particular compound. According to EEA Report No. 33/2016, the EU
supply of HFC-365mfc was approximately 6KT in 2014. We recommend reevaluating for accuracy.
Page 7, Section 2.1.1,
Remaining PFAS,
details production capacity estimates for PFHxS in
kilograms. Given our knowledge of the industry and vast production quantities of this particular
compound market, we believe PFHxS estimates should instead be captured in kilotons. We
recommend reevaluating these metrics for accuracy.
[Page 8, 2.2 Annual EEA import volumes (last 15-20 years)]
Page 8, Section 2.2,
Table 2: PFAS imported in the EEA from third countries (in tonnes),
consults
various different data sources to calculate the quantities of fluoropolymers, F-gases and other
PFAS imported into the EEA from third countries, including the Call for Evidence responses, data
retrieved from Eurostat’s International Trade in Goods database, and a literature review. In the
summary table, however, the tonnage for Fluoropolymers, 21,500, is sourced from 2015 and the
tonnage for F-gas is listed as 84,284, without a year. According to our understanding of the
literature, the figure for F-gas is 2019 data from EEA Report No. 15/2020.This would mean that the
summary table is consulting data, not only from different sources, but also different time-periods.
This presents a concern as comparing different time periods may distort the data and result in
misleading conclusions.
[Page 9, 2.2 Annual EEA import volumes (last 15-20 years)]
Page 9, Section 2.2,
F-gases,
points to data from the EEA 2020 Report on Greenhouse Gases that
show that total imports of fluorinated gases have “seen a decrease in the years preceding 2017-
19.” The paragraph then explains how import amounts decreased in 2019, when compared to
2017. Given the provided context, it is not immediately clear if “decrease” and/or “preceding” are
misplaced and misconstruing the significance of this data. We recommend updating this language
and clarifying if the intent was to compare import numbers in 2017 to 19 to years prior.
[Page 9, 2.2.1 Eurostat data]
Page 9, Section 2.2.1,
Table 2: A summary of annual imports of PFAS chemicals from third
countries into EU27 (tonnes),
is marked as the second table in the report but, based on preceding
and succeeding data sets, it is clearly the third. We suggest updating the table label for clarity.
Page 9, Section 2.2.1,
Table 2: A summary of annual imports of PFAS chemicals from third
countries into EU27 (tonnes),
states that the import and export information gathered through the
Eurostat source only represents approximately ¼ of all legal imports. Although we would agree
with this statement, we believe that using the data from the EEA Report No 15/2020, Fluorinated
greenhouse gases 2020 for imports and exports, as well as production, is more consistent.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
[Page 10, 2.2.1 Eurostat data]
Page 10, Section 2.2.1,
Table 4: A summary of annual imports of PFAS chemicals from third
countries into EU27 (tonnes),
cites F-gas volumes for 2019 at 10,371T. according to EEA Report
No. 15/2020, however, F-gas volumes for 2019 were 26KT, making the included figure vastly
below what’s recorded in available public literature. We recommend reevaluating the data set for
accuracy.
[Page 11, 2.3 PFAS production in the market]
Page 11, Section 2.3,
Table 5: Main global manufacturers of Fluoropolymer, F-gas and other
PFAS,
details the market share of major manufacturers of PFAS and fluoroplastics, along with their
operational locations. We noted that the source listed for Table 5 only captures fluoroplastics and
does not include F-gases, rendering it incomprehensive for this particular data set. We suggest
consulting another source for a clearer, more accurate assessment of manufacturing locations.
o
Concerning Chemours, it is listed as having locations in Germany, Japan, China, the
Netherlands, and the US. This is incorrect. Chemours does not have any production
locations in Germany or Japan.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0005.png
Application of Fluorinated Gases (F-Gases) in the European Economic
Area – Comments on Consultation Report Summary
Link to report summary:
https://bit.ly/3v8REKF
[Page 4, 2. Introduction]
Page 4, Introduction,
What are per- and polyfluoroalkyl substances (PFAS) and fluorinated gases
(F-gases)?
The definition of PFAS for this work covers any substance containing at least one -CF2
or -CF3 group within its chemical structure. We believe this definition is outdated and should be
updated.
Page 4, Introduction,
Why is there concern about them?
While we understand the concern
regarding the persistence of some PFAS and that of their degradation products, we believe that
these concerns have been addressed by requesting independent studies about TFA degradation
related to R-1234yf and to R-134a.
[Page 5, 3: Overview of the use of F-Gases and Emissions]
In general, we believe it is important to address in this section that early ammonia, methyl-chloride
and sulphur-dioxide refrigeration systems were the cause of numerous casualties. In particular, the
high number of casualties due to ammonia intoxication led to leave refrigerators in backyards and
triggered the need for the development of safer compounds, later called Freon™.
[Page 6, 3. Overview of the use of F-Gases and Emissions]
Page 6,
First Paragraph:
Greater specification regarding which substances degrade into persistent
substances such as trifluoroacetic acid (TFA) is needed.
Page 6,
First Paragraph:
When discussing the possible adverse environmental effects of persistent
substances, we believe it is important to reference the naturally occurring TFA in oceans, as well
as specify which reports contradict these findings as they are currently not specifically identified.
Page 6,
Table 1 Annual Usage, Stocks and Emissions of F-Gases in the EU27+Norway+UK:
We
have seen some inconsistencies in the figures reported in the 2
nd
Stakeholder Consultation
Questionnaire comparing the data from the Exponent International Report, the Report Summary F-
Gas Uses and the Report Summary Transportation. As an example, on page 136 of the 2
nd
Stakeholder Consultation Questionnaire, the total F-gases in the car park is estimated to be
184,130 MT, where on page 6 of the Exponent International Report, the amount in stock is 115,763
MT.
Regarding
emissions, in the 2
nd
Stakeholder Consultation Questionnaire on page 136, the annual
emissions are estimated to be 9,000 MT, which is aligned with the information in the Report
Summary F-Gas Uses and the Report Summary Transportation, however on page 116 of the 2
nd
Stakeholder Consultation questionnaire it is estimated as 11,726 MT, which is aligned with the
Exponent International Report.
We believe it is important that there is consistency in the numbers used in the different sections of
the 2
nd
Stakeholder Consultation Questionnaire and amongst the expert summary reports.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
[Page 7, 4.1 Refrigeration, Air Condition and Heat Pumps]
The market segmentation given is too wide. It would be more useful if specifics of each
subsegment were provided. More specifically, each macro-segment mentioned here should be split
into application segments identified by specific needs, available alternatives and socio-economic
analysis of non-F-Gas alternative technologies. We suggest the following breakdown:
o
Dividing Industrial Refrigeration into 2 to 3 sub-applications.
o
Subdividing Heat Pumps following the EHPA segmentation format, i.e. A-A; G-W; and A-
W. A-W could be further split into outdoor Monoblock and split applications.
o
Dividing Transport Refrigeration into trucks, trailers, small trucks, railways, marine
applications and air transportation.
o
Analyzing Heat Pumps for tumble dryers separately from industrial dryers with the creation
of a Home Appliances segment composed of tumble dryers, dish washers and washing
machines.
o
Industrial Dryers.
[Page 8. 4.1.1: Trends in Refrigeration, Air Conditioning and Heat Pumps]
Page 8,
First Paragraph on this Page:
It would be valuable to mention that R-1234yf is the main
refrigerant now used in mobile air conditioning of new cars.
Page 8,
Last Paragraph of Section:
Per our own analysis, Chemours has not seen a market
movement towards lower GWP HFO options in residential or commercial building applications.
[Page 8, 4.1.2: The Use of Alternatives in Refrigeration, Air Conditioning and for Heat Pumps]
Page 8: Broadly speaking, for each application segment, the non-identification of a satisfactory
alternative should lead to a socio-economic analysis of the consequences of such extended
restriction. Chemours provided its expert views on the risk of using alternatives for key segments,
which do not seem to have been taken into consideration in this report. Our expert view shared
with 4 of the 5 national competent authorities on June 24, 2021 have also been omitted. The safety
aspects of “alternatives” are largely underestimated and very lightly scrutinized in the RoI (See
notes in the HVACR and Transport documents for detailed actions).
Page 8,
Bulleted List:
It is important to specify what is the size of the charge when mentioning that
larger ‘charge sizes’ pose a risk of flammability when hydrocarbons are used in larger quantities.
Page 8,
First Paragraph after Bulleted List:
It would be of great value to further elaborate on the
specific areas where alternatives are unable to provide the conditions required for some processes.
In particular, more detail should be given on resource efficiency and using CO
2
as a refrigerant in
hypermarkets in high ambient temperatures. In our experience, an additional piece of equipment
would be needed for the condenser needs to be cooled down (to be able to reach an acceptable
level of efficiency for the system to operate, ) and/or an additional receiver is required for storing
the CO
2
in stand-still mode . When adding the above together, more resources are needed to
design, install and maintain the refrigeration system running on alternatives vs using a F-gas
solution with low GWP.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0007.png
[Page 9, 4.1.2: The Use of Alternatives in Refrigeration, Air Conditioning and for Heat Pumps]
Page 9,
First Paragraph on Page:
Greater detail on steps taken to reduce the risk of damage to the
cooling circuits of split units (part inside and part outside a building) is needed.
Page 9,
Second Paragraph, Last Paragraph of Section:
We echo the sentiments that industry has
previously raised that the cost of using CO
2
in mobile air conditioning is too high.
[Page 10, 4.2.2: The Use of Alternatives for Foam Blowing]
Page 10,
First Paragraph:
We believe the first statement that F-gases are persistent is not correct.
H(C)FOs are not persistent and have very low degradation of F-gases to TFA. Reference:
Published evidence supports very low yields of TFA from most HFOs and HCFOs - Fluorocarbons
https://www.fluorocarbons.org/publication/published-evidence-supports-very-low-yields-of-tfa-from-
most-hfos-and-hcfos/
[Page 10, 4.3 Solvents – Trends and Alternatives]
Page 10,
Second Paragraph:
It is important to mention that some alternatives have health
concerns and regulatory restrictions.
[Page 13, 4.6.1 Trends in Fire Suppressants]
Page 13,
Paragraph 2:
It is important to clarify that while the trend from HFCs to HFOs does not
apply to Fire Suppressants, the reason is not because HFOs are flammable, as the report
suggests. As a matter of fact, an HFO considered in this space is 1336mzz, which is non-
flammable.
[Page 15, 7. List of PFAS substances mentioned in this report]
The non-flammable HFO-1336mzz(Z) is missing in this table. Chemical name: cis-1,1,1,4,4,4-
hexafluoro-2-butene
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0008.png
Report summary F-gas uses – Comments on Consultation Report
Summary
Link to report summary:
https://bit.ly/3lLlr9n
[Page 3, 3. Tonnage Band]
Page 3, Section 3 explains how market data on F-gases filled into new products and in stocks each
year are primarily sourced through data collated by the “European Union (EU)/European Economic
Areas (EEA) Governments (the Greenhouse Gas (GHG) inventory data) in their annual reporting to
the UNFCCC (EU, 2020a)” and depicted in Figure 1. However, the cited data clearly stems from
different sources rather than solely the annual EEA report on Fluorinated greenhouse gases 2020.
We recommend revisiting the information sources is as it could pose consistency, coherence and
standardization issues. In addition, it’s unclear why domestic refrigeration demands were 122t of F-
gases for new products in 2018 since the (EU) 517/ 2014 has banned the placing on the market of
HFCs with GWP of 150 or more since January 2015 and most of the viable refrigerants do not
meet the 150 GWP threshold.
Page 3, Section 3 also breaks down the tonnage of F-gases by stage, whether it is filled into new
products or found in operating systems. According to the F-gas summary report, 19,724 tonnes/a
F-gases remain in products at decommissioning but there is no further explanation on end-use. It
would be helpful to have additional information on what has been done with the remaining F-gases
that are in products at the time of decommissioning and how the product is dealt with.
[Page 7, 5. Manufacturing & market price + market development Objectives of the study]
Page 7, Section 5 details market data for fire detection and suppression, indicating strong growth
over the period of 2018 to 2025 (Research and Markets, 2019). However, ‘Clean Agent
Suppression’ from F-gases is a very small, specialty portion of the fire detection and suppression
market. We estimate that ‘Clean Agent Suppression’ in developed countries has declined steadily
since 2010.
[Page 7, 7. Emissions]
Page 7, Section 7 claims that the estimated total emissions of F-gases from the “different sub-
applications” may be found in Appendix III. However, Appendix III only lists domestic, commercial,
industrial, and transport refrigeration, as well as mobile air and stationary air conditioning and heat
pumps. The listed applications in Appendix III are main sectors, not the described sub-applications.
For example, a sub-application would be residential heat pumps. We recommend revising
Appendix III for accuracy.
[Page 8, 7. Emissions]
Page 8, Section 7 unpacks how HFOs are being used commercially compared to other F-gases
and notes that the majority are used as a single substance (rather than a blend) in mobile air
conditioning (MAC) systems for passenger cars and in light goods vehicles and commercial
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
refrigeration, commercial air conditioning, heat pumps and process cooling. While it is true that
MAC systems are using a pure HFO, blowing agents for foams are using pure H(C)FOs as well.
However, the other main sectors, e.g. commercial refrigeration, are using HFO/ HFC-Blends.
Page 8, Section 7 also provides quantitative measures for HFO emissions from passenger and
light goods vehicle MAC in 2018. According to the summary, emissions from manufacturing ranges
from 9 – 1,170 tonnes/a, and emissions from stocks range from 1,281 – 17,472 tonnes/a. However,
that is the extent of the context provided for these ranges, omitting critical information. The
summary does not provide contextual reasoning for either figure range. And, for manufacturing
there is a vast delta that contradicts our understanding of the facts. Manufacturing of F-gases is
expected to have very low emissions and the given figure ranges are incongruent with that
expectation. We suggest revising this Section for accuracy and to provide clear and
understandable facts, especially since these emissions findings are reported annually to the
national authorities and are included in the GHG emission inventory reports to national authorities.
[Page 8, 8. Worker exposures]
Page 8, Section 8 deals with worker exposures to F-gases and notes that in plant manufacturing or
when putting gases into product, exposure should be small given the need to use closed systems,
a point made by numerous respondents. Outside of the manufacturing plants, the study argues that
there may be greater exposure for workers, including at sites reclaiming refrigeration equipment at
the end of its service life. This assertion, however, is incorrect. Exposure during end of life recovery
and recovery for reclamation is comparable with servicing exposure during operation. Further, it is
worth noting that any rise in exposure outside of manufacturing plants may very well be due to non-
adherence to industry best standards and practices for such work. Best handling practices exist
with demonstrably positive outcomes in EU Member States. When these practices are applied
appropriately, emissions outside of manufacturing plants, even during reclaiming and end of life
operations, would be reduced considerably.
[Page 8, 10. Alternatives]
Page 8, Section 10 delves into the alternative non-PFAS substances and technical methods that
were identified for different applications given the pivot away from F-gases for certain uses. While
the summary asserts that domestic refrigeration has moved away from a near total reliance on F-
gases to an almost total reliance on alternatives, Appendix III estimates that the demand of F-
gases for domestic refrigeration is still 122T in 2018. If the sector has phased out F-gases and is
nearly completely reliant on alternative substances, it is not immediately clear why 122T is still
being used in new products. It would be helpful to have clarity and additional context on this data.
Page 8, Section 10 also notes that the clothes dryer heat pump market is similarly pivoting away
from F-gases to alternative substances. If this assertion is correct, it would be helpful to understand
how this is feasible for commercial tumble dryers with higher charge sizes, which would inevitably
impact the safe use of any alternative substance.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
[Page 9, 10. Alternatives]
Page 9, Section 10 continues discussing the switch to alternatives across various applications and
notes that there is strong resistance to pivoting to alternative-use in the mobile air conditioning
market, with stakeholders citing safety concerns around hydrocarbons and cost concerns for CO2.
It would be helpful to understand how cost is being quantified in this context. While there is final
equipment cost in the market, there is also environmental costs of manufacturing, which is more
complex, and costs related to labor-intensive equipment.
Page 9, Section 10 also points to Appendix VII for an assessment of alternatives for each sub-
application of F-gas. This section notes that major constraints with these options include safety,
technical factors and legislation, but omits another significant factor for consideration when
evaluating alternatives, that of indirect environmental impact. Any alternative being considered
should also be evaluated in the context of sustainability, including resource efficiency, and
environmental impact for a comprehensive and truer comparison.
[Page 9, 11. Economic impacts in case of a full PFAS ban]
Page 9, Section 11 unpacks the economic impacts of restriction of PFAS and claims that F-gas blowing agents are
more expensive than the alternatives, with HFOs relative to CO2 mixes having a cost differential of x10 according to
stakeholder responses. Though the summary posits this as a strong rationale for switching to alternatives, it is worth
noting that this is not the present trend and thus not a fully accurate picture for the current cost state.
Page 10, 11. Economic impacts in case of a full PFAS ban]
Page 10, Section 11,
Table 1: The trend development and economic impact for each of the
different sub-applications
explains the trend development and economic impact for each of the
different sub-applications and there are several opportunities for additional context or clarity,
specifically:
o
For commercial refrigeration, this application needs to be divided into several sub-sectors,
including hypermarkets, supermarkets, discounters, condensing units, integrals and by
ambient conditions as the trends and impacts will differ and vary greatly depending on the
sub-sector. There are also differences by region, with variances including higher ambient
conditions and affordability. The summary also claims that there is growing acceptance of
the use of alternatives, namely CO2 and hydrocarbons in mid- to large-scale facilities in
the sector, but this does not appear fully correct. According to our understanding of the
industry, CO2 is not a preferred option and hydrocarbons have a charge size limit of 500g,
limiting its applicability in this context.
o
For commercial refrigeration, the summary also notes that the lifetime of medium and large
equipment spans up to 15-25 years, and that it would take 10-12 years to bring new
products to the market. Beyond timelines, it is also important to note that these new
products would in many cases have higher costs and higher environmental impacts than
the solutions they are intended to replace, both in terms of energy consumption and
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
manufacturing environmental cost. Resource efficiency must be included in this
assessment.
o
For industrial refrigeration, the summary posits that absent restriction, baseline F-gas use
is declining in favor of ammonia systems. This is not representative of the entire industrial
refrigeration spectrum, however, as ammonia is not an alternative for the majority of
applications. There is a clear industry convergence towards HFOs like R-1234ze for
multiple chiller applications, mainly due to its energy and cooling performance, as well as
its safety benefits. We would also mention the safety concerns linked with ammonia,
including high toxicity and flammability. We recommend that this context be included to
give a clearer picture of this segment.
o
For industrial refrigeration, the section admits that continued use of F-gases is likely to be
required to reach and maintain certain operating temperatures and the fact that F-gases
still provide the most cost-efficient option for some specific applications. We should also
note that F-gases provide the highest system efficiency and thus, the lowest environmental
impact as compared to equivalent CO2 emissions generated by energy consumption.
o
For transport refrigeration, the section posits that the sector will likely switch to HFOs in the
absence of an F-gas restriction given the high demand for refrigerated transport. Based on
our understanding of the industry, this pivot is likely to be towards HFO-blends rather than
pure HFOs.
o
For transport refrigeration, the section also notes that some alternatives are already in use
in trucks, trawlers and in reefer containers, although currently not widespread. Listed
barriers to widespread alternative adoption include size limitations, which are problematic
for the use of active CO2 systems given the layout of existing trucks. Beyond size,
however, cost and performance limitations should also be considered as barriers to
alternative adoptions in the event of a PFAS restriction. It is also worth noting that
concerns related to CO2 systems extend beyond “existing trucks” and should also include
refrigerated truckload trailers.
o
For transport refrigeration, the section admits that use of hydrocarbons in enclosed areas
may generate risks of flammability but fails to mention that the use of flammable
refrigerants is simply not allowed aboard vessels and is subject to limitations on trains and
in terminals, storage areas and metropolitan areas. Use of such an alternative in this
application would also generate considerable regulatory changes.
o
For transport refrigeration, the section also claims that there are significant gaps in the
market, meaning that reliance on F-gases in road transport refrigeration is likely to
continue for some time. We must be cognizant, however, that this gap goes beyond just
road transport refrigeration and includes sea and railways as well
o
For mobile air conditioning, major barriers for use of F-gas alternatives go beyond safety,
toxicity and cost. Performance is also a factor. For alternatives such as CO2, we must also
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
note that end-user cost increases would likely be long-term and ambient temperature
limitations would have to be overcome by new technological solutions.
o
For mobile air conditioning, the section also mentions do-it-yourself kits for topping up
MAC systems that may result in significant releases to the environment. To fully appreciate
this anecdote, it would be helpful if more information and context was provided about these
kits’ performance and use.
[Page 11, 11. Economic impacts in case of a full PFAS ban]
Page 11, Section 11,
Table 1: The trend development and economic impact for each of the
different sub-applications
continues to unpack trends and economic development by application.
Additional areas in need of amendment and clarification include:
o
For domestic AC and domestic heat pumps for space heating, the section notes that
building codes may need to be revised and precautions need to be recognized when
considering a switch to fluorine-free alternatives. We want to note that spaces being
accessed by people present certain limitations related to the safety risk for alternative
adoption as well.
o
For domestic AC and domestic heat pumps for space heating, the section also notes that
certain stakeholders raised concerns that there is no alternative to HFOs, specifically R-
1234yf, for the heat pump market because of the safety concerns related to hydrocarbons.
We noticed that neither R-32 nor blends are mentioned in this context. It is not clear why
they were not mentioned, and we would request that it be included to ensure a
comprehensive assessment.
o
For commercial AC and heat pumps, the section notes that propane is currently mostly
restricted to small applications because of building codes and other regulations that limit
charge size. However, this is not the full case. These applications require larger charging
sizes or they won’t be suitable for CO2 given the resulting cost and resource inefficiency.
Further, alternatives in this context present major safety concerns related to fire and
explosion risk and this caveat should be noted, not ignored.
o
For propellants (non-MDI), the section notes that, when considering alternatives, some
safety constraints should be recognized. Just as the succeeding Section 12.1
Other
impacts in case of a full PFAS ban
notes, an increased use of hydrocarbons would
increase atmospheric loading with volatile organic compounds. This caveat should be
reiterated in the impact section of Table 1 for propellants as well.
[Page 12, 12.1 Other impacts in case of a full PFAS Ban, Environmental]
Page 12, Section 12.1 lists emissions as a key environmental impact of switching from F-gases to
alternatives but admits that increased use of hydrocarbons would increase atmospheric loading
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
with volatile organic compounds (VOCs). This is important to note because it demonstrates how
even the chemistries with perceived low-concentration emissions can have detrimental
environmental impacts. This section also notes that the severity of this problem is dependent on
the quantity of propane that may leak from systems. If this argumentation is reasonable for
hydrocarbons, then it must also be applicable for TFA, a naturally occurring substance that can
also be produced by the breakdown of some HFCs or HFOs.
Page 12, Section 12.1 admits that a major health concern regarding a pivot from F-gases is the risk
of fire. It is not just fire that is the concern, however, it is also, and perhaps more worrisome, the
risk of explosion. We recommend this caveat be included for proper context.
[Page 12, 12.2 Other impacts in case of a full PFAS Ban, Social impacts]
Page 12, Section 12.2 lists reduced employment through loss of market share for EU companies
as a social impact of a full PFAS ban. We should also consider the impact on small to medium-
sized companies (SMEs) that would not be able to afford the expensive investments necessary to
accommodate a radical technology change if PFAS is removed from the market.
[Page 13, 12.2 Other impacts in case of a full PFAS Ban, Social impacts]
Page 13, Section 12.2,
Table 2: Summary of availability of alternatives to the use of F-gases in
New HVACR Systems
summarizes the availability of alternatives to the uses of F-gases in new
HVACR systems and there are several opportunities for additional context or clarity, specifically:
o
For domestic AC and heat pumps, hydrocarbon-based alternatives are listed as new
products already on the market, though there are calls for relaxation of the limits on charge
size. The summary fails to mention, however, that those limits are in place for proven
safety reasons. We recommend including this caveat for fair and comprehensive analysis.
The details for this section also list specific situations where alternatives may continue to
be problematic, including use in high rise buildings, where the risks of accidents may
exceed the risks from emissions of F-gases. This is an important caveat to note since
applications within this subsector that have charge limits exceeding 500g may not have the
option to switch to alternatives. For example, some national and local building codes are
not currently supporting hydrocarbon usage for this application. To ensure this detail is
adequately captured, domestic AC and heat pumps must be divided into application
segments, charge sizes and analyzed by regional/local differences.
o
For commercial HVACR, this sub-use is a substantial sector and should be divided into
application segments, charge sizes and analyzed by regional and local differences to
ensure all nuances are captured. Further, the summary points to further research being
conducted “in a number of areas”. Additional information as to what these “number of
areas” are would provide further insight into the available options in this sector. It is also
critical to note that alternative solutions like CO2 or hydrocarbons are not applicable for the
entire spectrum of this sector and even where it is applicable, there are significant costs to
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
consider including higher energy consumption which in turn leads to greater environmental
impact in terms of CO2 equivalent emissions.
o
For industrial heating and cooling, the section notes that efficient systems based on
ammonia have been in place for many years. And, while other alternatives to F-gases are
also practical for some industrial applications, there may be situations or processes where
the continued use of F-gases is required due to toxicity and flammability concerns linked to
the use of Ammonia. We recommend including this detail for full context.
o
For electronics cooling, the summary notes that very small systems may be cooled using
basic ventilation or small-scale AC systems for which hydrocarbon charge size would not
be problematic. However, this does not account for the safety concerns linked to the use of
a highly flammable refrigerant. For full context, we recommend including this caveat.
o
For transport refrigeration, the summary notes that some alternatives are already in use in
trucks, trawlers and reefer containers but such use is currently not widespread and specific
barriers affect the sector, including size limitations that are problematic for the use of active
CO2 systems given the layout of existing trucks. This problem also applies to
hydrocarbons. We must also note that this is an issue of safety as well, specifically the
safety restrictions applying to multi-modal transportation. Further, these limitations will be
compounded by regulatory changes and additional costs that will be projected on
consumers if PFAS is restricted.
o
For mobile air conditioning, the section includes an €300 estimate for the cost of adopting
CO2 MAC systems per vehicle. We would appreciate additional clarity as to how this
estimate was reached, given the variations in car model, size and design.
o
A footnote is included for both commercial HVACR and industrial heating and cooling that
states “the distinction between industrial and commercial HVACR is not clear cut” and “a
regulation on either sector would need to define very clearly what was covered.” We
support this comment and would also want regional sub-group differences to be analyzed
o
When mentioning restriction scenarios envisioned, namely “mainly total phase-out of
PFAS-based F-gases" it is important to also consider F-gases that might not fulfill the
PFAS criteria in the future.
[Page 14, 13. Methods used & uncertainties]
Page 14, Section 13 explains that emissions are calculated by multiplying activity data by
emissions factors. Emissions factors can be either default or specific to a country, application or
sub-application. According to the summary, the methodology for Member States to collect and
compile this data has been published in the Intergovernmental Panel on Climate Change (IPCC)
Guidelines for National Greenhouse Gas Inventories (IPCC, 2006). However, more information on
how the data is being aggregated and what process is being used would be helpful to
understanding the data.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
Page 14, Section 13 also lists uncertainties, including GHG inventory data, which we believe is
incomplete. Companies that are not required to report under the F-gas regulation do not have
access to the reporting tools and therefore any F-gases that they might destroy will not be included
in the reporting. Another element which is not included is the recycling of F-gases. There is no
tracking of the amount of F-gases that are recycled in the field and are therefore not emitted or
destroyed. EEA Report No 15/2020, Fluorinated greenhouse gases 2020 contains data reported by
companies on the production, import, export and destruction of fluorinated greenhouse gases.
Page 14, Section 13 argues that there is unclarity if the application stationary air conditioning
includes F-gases used in heat pumps. However, in Appendix II and III we believe that heat pumps
are included in the reported data. Further clarity needs to be shed on this information.
[Page 15, Appendix I]
Page 15, Appendix I includes a list of F-gas substances identified in commercial use through the
assessment. While all F-gases are indeed listed, this compilation ignores the renewed definition.
Under the renewed definition, HFC-32 should not be included. We suggest culling Appendix I for F-
gas substances that do not meet the criteria for the renewed definition or highlighting in some way
which F-gas substances no longer meet the renewed definition to ensure accuracy and clarity.
Page 15, Appendix I lists specific F-gas substances by substance, code and structure. Several F-
gas codes are listed twice, however. Specifically, F-gas codes HCFO-1233zd(E), HCFO-1224yd
and HFO-1234ze(E) are listed multiple times. It would be helpful if this were acknowledged in an
accompanying legend or if notes were provided to clarify the repetition if this is not an error.
[Page 17, Appendix II]
Page 17, Appendix II lists intended applications of the EU-28 total supply of F-gases, sourced from
“the F-gas Report (EU, 2020c). For foams, including pre-blended polyols, the values for 2016-2019
do not align with the values listed in Appendix III as “Foam Blowing Agent,” for open and closed
cells. Appendix II lists supplies for foam for 2016 as 10,157, 2017 as 11,521, 2018 as 11,083, and
2019 as 11,041, but Appendix III lists “new use” emission values of 4,940 and 271 for closed cells
and open cells, respectively. It would be helpful to understand how “new use” is being defined in
this context. In Appendix III, total emissions closed cells and open cells are also listed as 4,186 and
1,074, respectively. It would be helpful to understand how the values listed in Appendix III and
Appendix II are complimentary so the data sets can be fully understood.
Page 17, Appendix II denotes intended applications of the total supply of F-gases, however,
significant quantities of F-gases made in Europe are exported to non-EEA regions. It is unclear if
this is accounted for in the data, particularly pre-2015 volumes. Please clarify.
[Page 18, Appendix III. Estimated total emissions of F-gases from the different sub-applications.]
Page 18, Appendix III denotes the fire protection total emission rate at 3.48% of “installed systems”
based on the amount in stocks. Installed fire systems are generally non-emissive by nature and the
UNEP Halons technical options committee 2018 assessment report on P 88 estimates the global
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0016.png
emissions rate to be 2.5% in 2018. Given the advancement on service and maintenance of the
systems in the EU, we can expect the emissions rate in the EU to be lower than the global
estimate. This should be clarified to present a truer picture.
https://ozone.unep.org/sites/default/files/2019-04/HTOC_assessment_2018.pdf
[Page 22, Appendix V]
Page 22, Appendix V lists estimations for quantities of hydrofluoroolefins used as a proportion of F-
gases in products and equipment for EU-28 (2018) and points to a source (EU, 2020c) that is not
available. We recommend making this source document available for review, reference and
appropriate context.
Page 22, Appendix V includes a note at the end of the chart with a caveat that HFOs are mainly
used in mobile air conditioning and commercial refrigeration, based on stakeholder discussions.
Needs to be noted that HFOs are also used as Blowing Agents for foam.
[Page 23, Appendix VI]
Page 23, Appendix VI estimates emissions of HFOs in 2018 from passenger cars and light goods
vehicle mobile air conditioning, however the lack of detailed information provided is not substantive
enough to glean clear conclusions.
[Page 24, Appendix VII]
Page 24, Appendix VII lists identified alternatives to F-gases in the HVACR market, separated into
sub-application. Though the listed applications include domestic refrigeration, commercial
refrigeration, industrial refrigeration, electronics cooling, transport refrigeration, stationary air
conditioning, mobile air conditioning and heat pumps, it is far too limited. There are many more
applications that differ by region, affordability being a factor, and ambient temperature with system
temperature being another factor. Any comprehensive assessment of the availability of fluorine-
free alternatives in this market needs to be far more specific to present a full view.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0017.png
Electronics & energy – Comments on Consultation Report Summary
Link to report summary:
https://bit.ly/3aBrSFs
[Page 3, 1 Uses / Applications]
Page 3, Section 1: The section details the uses and applications of PFAS and particularly
fluoropolymers. However, we believe that the study failed to consider the uses of sulfur
hexafluoride (SF
6
) in electric power supplies, which according to the Life Cycle Assessment
(available here:
https://unfccc.int/sites/default/files/wamatt051_1.pdf)
the use of SF
6
technology
presents considerable environmental advantages over the use of SF
6
-free switch gear.
[Page 4, 3 Tonnage Band]
Page 4, Section 3: The SPIN database suggests that the most widely used substance in the
electronics industry in the United States and the Nordic countries is hydrofluorocarbon 1H-
pentaflouroethane, which is mainly used as a heat transferring agent and cooling agent, which is a
substance that is already regulated by the EU F-gas regulation.
Page 4, Section 3: It was difficult to discern the volume because markets have clearly been mixed.
For example, the SPIN database has a combined category for flame retardants and extinguishing
agents, making it impossible to distinguish between them. Greater detail on the breakdown of
these categories would be useful to providing a deeper assessment.
[Page 5, 3 Tonnage Band]
Page 5, Section 3: We believe a deeper breakdown of the 4,475 calculated tons of PFAS in dust
from e-waste dismantling areas would be beneficial especially between PFAS polymer and non-
polymer PFAS .
Page 5, Section 3: The report predicts that for immersion cooling the current EEA market is said to
be 0 tons, with a potential of 1,100 tons in 2025. Volume outlook is difficult to predict, however. The
technology is only emerging and still under development. Two technologies are emerging with
single-phase liquid or two-phase liquid cooling and it is unclear what each of their adoption will be.
[Page 6, 3 Tonnage Band, Table 3]
Page 6, Section 1, Table 3,
Batteries:
A narrower breakdown of the category would be helpful to
better evaluate the tonnage provided.
[Page 8, 5 Manufacturing and Market]
Page 8, Section 5,
Immersion Cooling:
While the summary report argues that the potential for
emissions from two-phase liquid immersion cooling systems is higher, we believe it is important to
note that systems can be designed to reduce the fugitive emissions and industry is developing
hermetic systems, which imply zero emissions. Technology is still emerging and being developed
to reduce the amount of fluid needed, which could reduce costs. This is important because the
report argued that the cost of the fluids was higher than the cost reductions provided by the
energy-efficiency of the system. Additional benefits of F-gases in immersion cooling include the
possibility for recycling and circular-use. (See this EPA industry example with the SF
6
high circular
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0018.png
reclaim and recycling:
https://www.epa.gov/sites/default/files/2018-
08/documents/12183_sf6_partnership_overview_v20_release_508.pdf.)
[Page 9, 5 Manufacturing and Market]
Page 9, Section 5,
Immersion Cooling:
At the end of the section, regarding PFAS emissions from
immersion cooling, the estimated emissions for the EU of 1.1 t/y does not consider how the
industry is developing hermetic systems.
[Page 9, 6 Number of Production Sites]
Page 6, Section 6: We believe it is important to note that major original equipment manufacturers
(OEMs) are in the United States. Additionally, we feel like this section should also include
production sites in Asia.
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0019.png
Transportation – Comments on Consultation Report Summary
Link to report summary:
https://bit.ly/3aBrVkC
[Page 4, 1 Uses / Applications]
Page 4, Section 1, Table 1: The report’s table on “Uses and applications of PFAS in transportation
products and articles” states no information is available on fire prevention and protection uses. In
fact, F-gases are used as fire suppression systems in military applications, cultural property, data
centers and other critical installations. Performance requirements for these applications include
electrical non-conductivity and non-corrosiveness, as well as low residues after utilization.
[Page 5, 2 Main PFAS substances]
Page 5, Section 2, Table 2: The section lists a few examples of F-gases used in transportation but
marks the information regarding current use in the EU transport market as “unknown.” All new air
conditioning systems in cars manufactured in the EU make use of R-1234yf, a low-GWP
refrigerant, in compliance with the F-Gas phase down program under the EU F-gas Regulation. R-
1234yf blends are also used in a wide variety of transport refrigeration equipment, where those
blends have progressively replaced high-GWP refrigerants.
[Page 6, 4 Emissions]
Page 6, Section 4: The summary report assumes emissions of F-gases to the air of 5% (ERC 9b
Widespread use of functional fluid (outdoor), ECHA 2015), for a total estimated emission of 9,000
t/a of F-gases from HVAC systems for passenger comfort in road traffic. The emissions to air value
of 5% is overly conservative and not representative of present industry standards. It fails to reflect
the growing trend towards leak-proof A/C systems. Several studies (see our response to the
Stakeholder Consultation) indicate operational emission rates <2%/a.
[Page 6-7, 5 Exposure (workers, consumers)]
Page 6, Section 5: Given there is limited information available to the dossier submitter on PFAS
concentrations and exposure to PFAS in transport products, it is important to clarify that the vast
majority of transport HVACR equipment are close circuit, sealed systems. Exposure to workers is
regulated by handling and maintenance and repair (M&R) procedures. Exposure to consumers, on
the other hand, is essentially limited to mechanical accidents.
Page 7, Section 4, Table 4: The “HVACR-systems in transportation vehicles (F-gases)” subgroup
does not take into account refrigerated transport applications outside trucks. These uses include
the below applications, but this list is not complete:
o
Reefer containers: Ca. 5kg / unit
o
Refrigerated sea vessels: Ca. 200kg / vessel
o
Refrigerated wagons: Ca. 4kg / wagon
o
Air refrigerated containers: Ca. 0.2kg / container...
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0020.png
[Page 7, 6 Alternatives]
Page 7, Section 6.1: The summary report accurately states that manufacturers of transportation
vehicles do not prescribe the use of individual substances to their supplier but rather stipulate
performance specifications the individual parts have to meet. That said, system design is heavily
influenced by the thermodynamic properties of the heat-carrying substance. Present generation
equipment can hardly allow a substance change without a substantial re-design effort by system
manufacturers.
Page 7, Section 6: The summary report assumes that since the production of fluorine containing
materials usually is more expensive compared to most other materials, fluorinated materials are
used only where performance requirements leave no other option. This statement ignores two key
industry enablers in transportation, however, one being knowledge and know-how and the other
being availability of solutions. Furthermore, HVACR total system costs are heavily influenced by
the heat-carrying fluid choice made by manufacturers.
[Page 10, 6.5. HVAC-systems in transport vehicles (Alternatives)]
Page 10, Included in the Alternatives enumeration the Natural Gas HC-600 (n-butane) has been
mentioned. It’s not a suitable alternative due to the disadvantages of its safety profile and its
relatively high boiling point versus the current F-gas solutions. This results in a too low of pressure
to support sufficient thermodynamic performance.
Page 10, CO2 presents a particular challenge in automotive because its pressure is significantly
higher in the HVAC system than R-1234yf and HFC-134a, 10 x (Papasavva, 2014). It has been
difficult to contain CO2 in the flexible hoses needed to manage vibration during vehicle use. In
addition, a leak in the CO2 system can lead to high levels of CO2 in the cabin without being easily
detected when inhaling, which could be deadly. In the case of HFOs, the pressure in the system is
much lower (10x), hence the amount of refrigerant that can potentially leak into the cabin is much
lower. Reference: (Papasavva, 2014, page 8, paragraph 7, CARBON DIOXIDE (R-744)):
https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2474&context=iracc
Page 10, Since 2009 the automotive industry made tremendous improvements on the efficiency of
its air conditioning systems with the adoption of R-1234yf. ICCT Report (2019, pages 24-25) shows
in hotter climate conditions the lifetime emissions of an R-1234yf system are lower than those for a
R-744 system. The low GWP R-1234yf technology developed for the automotive industry can also
be applied to train rolling stock where a shift to low GWP R-1234yf will offer similar benefits.
Reference:
http://www.igsd.org/wp-content/uploads/2019/03/ICCT-IGSD-Mobile-AC-2019.pdf
[Page 11-12, 6.6 Interiors]
Page 12, Section 6.6, Table 5: The table on reported alternatives for PFAS substances used in
transport lists advantages and disadvantages of alternatives. It is appropriate to complement this
information on the “HVAC-systems in transport vehicles” sub-use section with the following:
EUU, Alm.del - 2022-23 (2. samling) - Supplerende svar på spørgsmål 49: Spm. om, hvilke interessenter, virksomheder mv. ministeriet har været i dialog med i forbindelse med ønsket om at indføre et forbud imod anvendelsen af PFAS, til miljøministeren, kopi til udenrigsministeren
2698302_0021.png
o
Disadvantages: alternatives can add higher system total carbon emissions, as well as
insufficient thermodynamic performance to reach the required scope. Known alternatives
can be complex to utilize and maintain, and they cannot provide sufficient levels of
equipment reliability. Additionally, many non-PFAS alternatives such as CO2 and water
provide lower resource efficiency than systems that run on F-gases.